RESINMUX=DISABLE, RESSEL=RES0
Operational Amplifier Mux Configuration Register
POSSEL | OPAx Non-inverting Input Mux |
NEGSEL | OPAx Inverting Input Mux |
RESINMUX | OPAx Resistor Ladder Input Mux 0 (DISABLE): Set for Unity Gain 1 (OPANEXT): Set for NEXTOUT(x-1) input 2 (NEGPAD): NEG pad connected 3 (POSPAD): POS pad connected 4 (COMPAD): Neg pad of OPA0 connected. Direct input to support common reference. 5 (CENTER): OPA0 and OPA1 Resmux connected to form fully differential instrumentation amplifier. 6 (VSS): VSS connected |
GAIN3X | OPAx Dedicated 3x Gain Resistor Ladder |
RESSEL | OPAx Resistor Ladder Select 0 (RES0): Gain of 1/3 1 (RES1): Gain of 1 2 (RES2): Gain of 1 2/3 3 (RES3): Gain of 2 1/5 4 (RES4): Gain of 3 5 (RES5): Gain of 4 1/3 6 (RES6): Gain of 7 7 (RES7): Gain of 15 |